110mm Soil Pipe Fittings — Pushfit Connectors, Socket Plugs, Bends, and Branches for UK Plumbers
110mm Soil Pipe Fittings — Pushfit Connectors, Socket Plugs, Bends, and Branches for UK Plumbers
110mm soil pipe is the standard above-ground drainage diameter in UK domestic and commercial properties. It carries WC waste from toilets to the soil stack, connects soil stacks to underground drainage, and forms the main vertical drain run in two-storey homes. Getting the right fittings — socket plugs, bends, branches, and couplings — is essential for a clean, leak-free installation that meets Building Regulations Part H.
This guide covers pushfit 110mm fittings for above-ground systems, the difference between grey and black versions, how to size branches, and when solvent-weld is required instead of pushfit.
Aquaflow 110mm Pushfit Waste Socket Plug — Grey
The most widely used 110mm fitting for capping off access points and sealing inspection points on soil stacks. The pushfit seal requires no tools and allows removal for rodding access. Essential when commissioning a new stack — fit plugs to all unused openings before water tests.
- Pushfit seal — no solvent weld required
- Removable for drain inspection and rodding
- Suitable for indoor and sheltered outdoor use
- Compatible with all standard 110mm soil pipe systems
£2.03 — View product
Aquaflow 110mm Pushfit 90° Knuckle Bend — Double Socket Black
Used to change direction at 90° on horizontal drain runs and at the base of soil stacks where the stack meets the underground drain. The swept 90° version has a larger radius and is preferred for WC connections to maintain self-cleansing velocity. Standard short-radius 90° bends suit access point and inspection chamber connections.
- Standard (short radius) for direction changes on horizontal runs
- Swept 90° (long radius) recommended for WC branch connections
- Pushfit rubber seal — ring must face flow direction
- Available in grey (above-ground) and black (UV-resistant for external)
£8.66 — View product
110mm D/S Branch 92° Pushfit
A 92.5° single-branch tee fitting for joining a WC outlet or branch waste into an existing vertical soil stack. The double-socket design accepts 110mm pipe on both the main run ends, with the swept branch entry at 92.5° for a turbulence-free junction. Standard fitting for WC connections to a soil stack.
- 92.5° swept branch — reduces blockage risk at WC junctions
- Double socket pushfit — no tools, no solvent required
- Pushfit rubber seal — suitable for soil and vent stack connections
- 110mm nominal bore — BS EN 1451 compatible
£10.62 — View product
Aquaflow 110mm Pushfit 45° Single Socket Spigot Bend — Black
45° bends are used in pairs to offset a soil stack around structural obstacles (RSJ beams, floor joists, lintels) without sharp direction changes that cause blockages. A 45° offset pair should maintain the same pipe centreline distance — calculate the required offset length before ordering. Also used at the top of the stack to form the rain cowl connector.
- Use in pairs to create offset — calculate offset depth first
- Maintain 1:80 minimum fall on horizontal sections
- Push-fit — both sockets face the same direction
- Grey for internal, black for external UV exposure
£5.53 — View product
Soil Pipe vs Waste Pipe: Know the Difference
110mm pipe is specifically soil pipe — it carries WC (foul) waste containing faecal matter and urine. This distinguishes it from waste pipe (32mm, 40mm, 50mm) which carries sink, basin, bath, and shower waste. The two systems must not be confused:
| System | Diameter | Use | Colour |
|---|---|---|---|
| Soil pipe | 110mm | WC, urinals, bidets | Grey or black |
| Large waste | 50mm | Kitchen sinks, commercial | White, grey, black |
| Standard waste | 40mm | Bath, shower, sink | White, grey, black |
| Small waste | 32mm | Basin, hand wash | White, grey, black |
Soil pipe connects directly to the underground drainage system (100mm vitrified clay or uPVC) via an adaptor at ground level. Never connect 40mm waste pipe directly to a 110mm soil stack without a trap — the pressure differential will siphon traps and allow sewer gas into the property.
Pushfit vs Solvent Weld for 110mm Soil Pipe
When to use pushfit
Pushfit is the correct choice for above-ground soil systems in domestic properties. The rubber ring seal accommodates thermal expansion — 110mm uPVC pipe expands by approximately 0.5mm per metre per 10°C change in temperature. Without this movement allowance, rigid solvent-welded systems crack at joints in cold weather.
Pushfit fittings also allow dismantling for maintenance, blockage clearance, and future extensions. This is particularly important on soil stacks serving multiple floors where access for rodding must be preserved.
When to use solvent weld
Solvent cement is used for below-ground drainage systems (usually 110mm or 160mm HDPE/uPVC buried underground) and where pipework is permanently concealed in concrete or render. Above-ground runs that will be accessible — in ducts, voids, or boxed-out areas — should remain pushfit for future access.
Note: 110mm above-ground fittings (pushfit, grey/black) are not interchangeable with underground drainage fittings (solvent weld, orange/cream). The sealing systems are different.
Grey vs Black 110mm Fittings
Both grey and black 110mm fittings are made from uPVC and have identical pressure and flow ratings. The difference is UV resistance:
- Grey — standard internal use, protected roof spaces, ducts. Not suitable for prolonged UV exposure (yellows and becomes brittle).
- Black — UV-stabilised, for external soil stacks, exposed pipework on building facades, or any run that receives direct sunlight.
Where a soil stack exits through an external wall and runs down the face of a building — common on terraced houses without internal stacks — use black fittings throughout the external section. Grey fittings can be used inside the building up to the point of exit.
Planning a 110mm Soil Stack Installation
Sizing and falls
Above-ground soil pipe typically uses a near-vertical stack (less than 5° from vertical) with branches connecting at 92.5° for WC waste. Horizontal branch runs should be kept as short as possible (maximum 6 metres from WC to stack for 110mm pipe) and must fall at 18mm per metre minimum (1:56) or up to 90mm per metre maximum (1:11).
Outside this range, self-cleansing velocity is not maintained — too flat and solids settle; too steep and the liquid outpaces the solids, leaving them stranded.
Air admittance valves vs open ventilation
The soil stack must be ventilated to prevent siphoning of traps. Two options:
- Open vent pipe — stack terminates above roof level with a cowl, at least 900mm above any opening window within 3 metres (Building Regs Part H).
- Air admittance valve (AAV) — where an open vent is impractical (flat roofs, loft conversions), a Durgo-type AAV can be used. It must be fitted in an accessible, ventilated location. Check local Building Control — some require open vent on the primary stack even when AAVs are used on branch runs.
Access and inspection points
Fit an access plug or rodding eye at the base of every soil stack and at each change of direction on long horizontal runs. Building Regs Part H requires access at every junction where a blockage cannot be cleared from a terminal point. Aquaflow socket plugs serve this purpose — they push in to seal and pull out for rodding.
Common Fittings Reference
| Fitting | Use | Notes |
|---|---|---|
| Socket plug | Cap unused openings; rodding access | Pushfit, no tools |
| 90° bend | Direction change; base of stack | Use swept 90° for WC waste |
| 45° bend | Offset pairs; top of stack | Use in pairs for offset |
| Single branch 92.5° | WC connection to vertical stack | Single or double inlet |
| Double branch 92.5° | Two WCs on same floor level | Must check flow rates |
| Strap boss | Add waste inlet to existing pipe | Core drill + saddle seal |
| Offset coupler | Join two pipes in line | For extending runs |
| Expansion coupling | Long horizontal runs | Allows thermal movement |
| Roof cowl | Terminate stack above roof | Keeps out vermin and rain |
| Underground adaptor | Connect above-ground 110mm to underground drain | Checks required for pipe material compatibility |
Fixing and Support
Support 110mm soil pipe at maximum 1.2 metre intervals on vertical runs and 0.5 metre intervals on horizontal runs (BS EN 12056 guidance). Use pipe clips with rubber inserts to reduce transmitted noise — important on internal stacks in timber frame or masonry party wall construction where Building Regs Part E (sound) applies.
On vertical stacks, one fixing per storey should be a fixed point bracket that prevents vertical movement; other fixings should be sliding/guide brackets that allow thermal expansion. This is critical on tall stacks — a 4-storey run of 110mm pipe can move 8mm vertically between summer and winter.
Water Testing a New Soil System
Before concealing pipework, test the system with a water test: fit socket plugs to all lower openings, fill the stack with water to the highest point, and check for leaks at all joints over 30 minutes. Building Control may require a test certificate before signing off Part H drainage works.
Use the Aquaflow pushfit socket plugs as test plugs — they seal adequately for a static water test. For pneumatic air tests required on commercial projects, use dedicated inflatable test bags.
Related Guides
- Waste Pipes and Traps — 32mm and 40mm Push-Fit, Solvent Weld, and ABS Fittings
- Toilet Cistern Maintenance — Fill Valves, Flush Valves, and Pan Connectors
- Flexible Tap Connectors and Isolation Valves
- Wet Underfloor Heating Systems — Manifolds and Pipe Layouts
- Bathroom Extractor Fans — Humidity Sensors, Timers, and Part F Compliance
Leave a comment